Wiring Instructions for WC-ASOKIT
1. Turn off unit and unplug from power source.
2. Remove blower duct.
3. Remove the two #2 square headed screws from the top of the unit and remove the top.
4. Unplug the pump and motor at the top of the electrical corner.
5. Remove the two #2 square headed screws from the electrical corner and remove the
corner.
6. Remove the paper from the double-faced tape on the back of the relay. Stick the relay to
the aluminum frame on the inside of the electrical corner approximately 5" from the top of
the frame; ensuring the terminals are pointing downward. See diagram.
7. Remove the grate and pads from the side of the unit to the left of the electrical corner.
8. Utilizing the electric screwdriver and the 5/16" hex head bit, attach the supplied pump brace
to the blower with the two self-tapping screws from the hardware bag. This should be done
in the same manner as the pump is attached, but place it on the left side of the blower and
ensure the bottom of the brace is 2" from the bottom of the reservoir.
9. The float switch is already attached to the supplied pump brace with an 8" cable tie. Ensure
there is 3" of cord from the right side of the pump brace to the float and that the float does
not hit the frame (See diagram).
10. Run the cord for the float switch up through the bottom of the aluminum frame on the
electrical corner.
11. Remove the cord connector. It is located at the bottom of the electrical corner.
12. Drill a 31/64" hole in the electrical corner approximately 7/8" below the switch, and insert
the indicator light into the hole. See diagram.
13. Place the female disconnect on the indicator light labeled L1 on Post 5 of the relay.
14. Remove the blue spade connector and wire from the L position on the switch with a Phillips
head screwdriver, and insert the spade connector from the jumper labeled A into the L
position on the switch.
15. Cut the black wire from the power cord just below the blue connector and then strip ½" of
plastic from the black wire.
16. Twist the bare end of this wire together with the L2 wire from the indicator light, the A
jumper from the switch, and the jumper labeled B that comes from Post A on the relay.
Connect all four of these wires together with a red wire nut from the hardware bag.
OPTIONAL ACCESSORIES
Automatic Shutoff O
tion
The Automatic Shutoff Option (WC-
SOKIT)
is available at the time of your WayCool
®
purchase or as a retrofit kit on a previously
purchased WayCool
®
.
The WC-ASOKIT shuts off the pump when
the water level gets low and prevents the
pump from damage. The warranty on the
pump is void if it is run dry.